Description
Powersoft Amplifiers Ottocanali 4K4
Overview
The Ottocanali 4K4 is a flexible and reliable 8-channel power amplifier with up to a total of 4,000 W at 4Ω, ideal for multi-zone applications in small to mid-scale installs. Ottocanali 4K4 supports any combination of lo-Z loudspeakers, mono-bridgeable channel pairs and 70V/100V Hi-Z distributed lines with no need for output step-up transformers.
The Ottocanali 4K4 features switchable main/aux signal inputs and offers a wide range of system control, alarms, GPI/O, and monitoring functions as well as sound shaping options.
The Ottocanali 4K4 implements universal switch mode power supplies with PFC and patented SRM (Smart Rails Management) technology maximizing reliability & efficiency and reducing power consumption.
Powersoft’s legendary efficiency saves valuable energy, keeping both operational cost and ‘carbon footprint’ at a minimum: the Ottocanali 4K4 shines with outstandingly low power consumption and heat dissipation. This dramatically reduces costs from the AC mains supply and air conditioning/cooling systems – not to mention the benefits to the environment for a greener planet.
MyPowersoft services are available for this product.
Features
Power supply
- Redundant universal switch mode power supply up to 400VAC tolerant with Power Factor Correction
- Patented output filter with ripple cancellation network
- Low Inrush Limiting reduces AC inrush current, removing the need for expensive power sequencers
- Detachable AC mains cable with IEC C19/22.2 (16A for EU, 20 A for the USA) socket
Protections
Fully protected circuit design with:
- Ac protection: shut down the power supply when AC mains voltage is outside the operating range
- Clip limiter: prevents severely clipped waveforms from reaching loudspeakers, while still maintaining full peak power output
- DC protection: protects against infrasonic signal at the outputs
- VHF protections: protects the loudspeakers against nonaudible, strong, non-musical high-frequency signals
- Short circuit protection: protects the amplifier from short circuit or other stressful events for the output circuits with automatic protection reset
- Long-term limiter: protects the loudspeaker against steady long-term RMS (nonaudio) signals, by reducing the maximum output
- Thermal protection: output stages operating temperature up to 80 °C (176 °F)
- Temperature-controlled continuous variable speed fan, front-to-back airflow
General
- Fixed frequency switchmode output stage for high-grade sound accuracy
- All models 2 RU for reduced rack cost and space
- Lightweight – for easier racking and shipping: 14 kg / 30.8 lbs
- Standard Phoenix connectors: analog and digital input, audio outputs, aux supply, alarms, and GPIO
- Remotely switchable double input (main and aux) per channel
Loudspeaker system configuration
- Direct drive either low impedance loads or 70V / 100V Hi-Z distributed lines
- Switchable 35Hz / 70Hz high pass filter per channel
- Mixed configuration with Lo-Z/Hi-Z systems possible
- Bridged mode, with low impedance, per channel pair
Alarms and GPIO
- General Purpose Input/Output alarm interfaces:
- dangerous DC in the output power signal
- thermal stress
- Configurable alarm contact NC/NO per channel
- Remote AUX input / MAIN input switch
- Remote ON/OFF switch
- PWS OUT connector providing up to 24VDC
Specifications
GENERAL | |||
Output power per channel | |||
Output power per channel | 450 W @ 2 Ω | 500 W @ 4 Ω | 250 W @ 8 Ω |
Bridge mode | 900 W @ 4 Ω | 1000 W @ 8 Ω | |
Max output voltage / current | |||
Max unclipped output voltage @8 Ω | 65 Vpeak | ||
Current | 15 Apeak | ||
AC MAIN POWER | |||
Power supply | Universal, regulated switch mode with PFC (Power Factor Correction) | ||
Nominal power requirement | 100-240 V ±10%, 50-60 Hz | ||
Operating voltage | 90 V – 264 V | ||
Power consumption/current draw | |||
Idle | 115 V: 47 W – 0.75 A | 230 V: 50 W – 0.7 A | |
1/8 of max output power @ 4 Ω | 115 V: 740 W – 6.6 A | 230 V: 750 W – 3.9 A | |
THERMAL | |||
Operating temperature range | 0° – 35° C – 32° – 95° F | ||
Thermal dissipation* | |||
Idle | 115 V: 160 BTU/h – 41 kcal/h | 230 V: 170 BTU/h – 43 kcal/h | |
1/8 of max output power @ 4 Ω | 115 V: 801 BTU/h – 202 kcal/h | 230 V: 839 BTU/h – 211 kcal/h | |
1/4 of max output power @ 4 Ω | 115 V: 1340 BTU/h – 338 kcal/h | 230 V: 1340 BTU/h – 338 kcal/h |